4 - Poster Test Chamber is a large-scale professional testing equipment that combines a multi-channel tire-coupled road simulation system (four-post test rig) with a high- and low-temperature environmental climate chamber. It is used to simulate road spectrum vibration during vehicle driving under controlled extreme temperature and humidity conditions.
4 - Poster Test Chamber is a large-scale professional testing equipment that combines a multi-channel tire-coupled road simulation system (four-post test rig) with a high- and low-temperature environmental climate chamber. It is used to simulate road spectrum vibration during vehicle driving under controlled extreme temperature and humidity conditions.
|
Model |
CZ-AHA-331D-WSOS (Customizable) |
|
Test chamber internal dimensions (W×D×H) (mm) |
7200×9200×5000 |
|
Door dimensions (W×H) (mm) |
3500(1750+1750)×3000 |
|
Temperature Range |
-40℃ ~ +80℃ |
|
Heating / Cooling Rate |
-40°C ~ +80°C, ≤120 min, average ≥1.0°C/min (With load, static no heat load) |
|
Humidity Range |
10% ~ 95% R.H (Within the temperature range of 20°C ~ 60°C) |
|
Solar Simulation |
600–1200 W/m² (Wavelength 280–3000 nm), stepless adjustment, irradiance area: 6000×2500mm |
|
Fresh Air System |
Minimum dew point temperature: -40°C, minimum airflow ≥400 m³/h; At an ambient temperature of 20°C, minimum airflow ≥1000 m³/h |
|
Air Velocity |
Under the premise of ensuring the temperature uniformity performance of the environmental chamber, the internal air velocity should be kept as low as possible, ensuring an average air velocity of ≤0.8 m/s at the vehicle position on the four-post system. |
|
Four-Post System |
Third-party supplier |
|
Model |
CZ-AHA-331D-WSOS (Customizable) |
|
Test chamber internal dimensions (W×D×H) (mm) |
7200×9200×5000 |
|
Door dimensions (W×H) (mm) |
3500(1750+1750)×3000 |
|
Temperature Range |
-40℃ ~ +80℃ |
|
Heating / Cooling Rate |
-40°C ~ +80°C, ≤120 min, average ≥1.0°C/min (With load, static no heat load) |
|
Humidity Range |
10% ~ 95% R.H (Within the temperature range of 20°C ~ 60°C) |
|
Solar Simulation |
600–1200 W/m² (Wavelength 280–3000 nm), stepless adjustment, irradiance area: 6000×2500mm |
|
Fresh Air System |
Minimum dew point temperature: -40°C, minimum airflow ≥400 m³/h; At an ambient temperature of 20°C, minimum airflow ≥1000 m³/h |
|
Air Velocity |
Under the premise of ensuring the temperature uniformity performance of the environmental chamber, the internal air velocity should be kept as low as possible, ensuring an average air velocity of ≤0.8 m/s at the vehicle position on the four-post system. |
|
Four-Post System |
Third-party supplier |