Vehicle Temperature and Sunlight Simulation Test Chamber


Vehicle Temperature and Sunlight Simulation Test Chamber can simulate the climate conditions required for whole-vehicle environmental performance testing, such as temperature, humidity, air velocity, and solar irradiance. It is suitable for performance testing of passenger cars, light trucks, and heavy trucks.

Vehicle Temperature and Sunlight Simulation Test Chamber can simulate the climate conditions required for whole-vehicle environmental performance testing, such as temperature, humidity, air velocity, and solar irradiance. It is suitable for performance testing of passenger cars, light trucks, and heavy trucks.



Product Details

Model

CZ-AH-SOR-840

Test Chamber Dimensions (W×H×D) (mm)

6000×7000×20000=840m³ (Customizable according to customer site conditions)

Door Dimensions (W×H) (mm)

5000x4000

Temperature Range

-50℃ ~ +80℃(-40℃, -20℃)

Humidity Range

20%R.H ~ 95%R.H (Temperature range: +10°C ~ +60°C), while maintaining a minimum controllable humidity of 30%R.H within the temperature range of -15°C ~ +10°C

Air Velocity

Vehicle speed simulation tracking fan, maximum air velocity 200km/h, adjustable air outlet

Solar Simulation

Radiation intensity: 500–1200W/m² (Wavelength 280–3000nm), stepless adjustment

Fresh Air System

Minimum dew point temperature: -40°C, adjustable airflow 500–3000m³/h

Exhaust System

Adjustable exhaust pressure differential, adjustable airflow 2000 ~ 6000m³/h

Dynamometer System

Paired with a third-party system

 

Model

CZ-AH-SOR-840

Test Chamber Dimensions (W×H×D) (mm)

6000×7000×20000=840m³ (Customizable according to customer site conditions)

Door Dimensions (W×H) (mm)

5000x4000

Temperature Range

-50℃ ~ +80℃(-40℃, -20℃)

Humidity Range

20%R.H ~ 95%R.H (Temperature range: +10°C ~ +60°C), while maintaining a minimum controllable humidity of 30%R.H within the temperature range of -15°C ~ +10°C

Air Velocity

Vehicle speed simulation tracking fan, maximum air velocity 200km/h, adjustable air outlet

Solar Simulation

Radiation intensity: 500–1200W/m² (Wavelength 280–3000nm), stepless adjustment

Fresh Air System

Minimum dew point temperature: -40°C, adjustable airflow 500–3000m³/h

Exhaust System

Adjustable exhaust pressure differential, adjustable airflow 2000 ~ 6000m³/h

Dynamometer System

Paired with a third-party system

 


Get Your Free Sample Now
Submit this form and our sales representative will contact you soon.
*Name
Phone
*Email
Company
*Message